Show simple item record

dc.creatorUnited States. Army. Air Service. Engineering Division.en_US
dc.date.accessioned2018-08-01T14:11:38Z
dc.date.available2018-08-01T14:11:38Z
dc.date.created1921-04-30en_US
dc.identifier.urihttp://hdl.handle.net/11200/49195
dc.descriptionThe object of these tests was to determine whether or not the magnetically operated starting switches supplied by the Bijur Motor Appliance Co., Hart Manufacturing Co., and the United States Light & Heat Corporation were satisfactory for airplane use. The Bijur switch is unsatisfactory. The Hart switch and the U.S.L. switch are satisfactory for production.en_US
dc.formatPDFen_US
dc.publisherWashington, D.C. : Chief of Air Serviceen_US
dc.relation.ispartofseriesAir Service information circular (Aviation) ; v. 3, no. 214en_US
dc.relation.ispartofseriesMcCook Field report ; Serial no. 1478en_US
dc.subjectAirplanes--Parts--Testingen_US
dc.subjectAirplanes--Motors--Partsen_US
dc.subjectAirplanes--Design and constructionen_US
dc.subjectElectric switchgearen_US
dc.subjectAeronautics--Systems engineeringen_US
dc.titleOperating tests of magnetically operated starting switches (equipment section test report)en_US