This Is AuburnAUrora

Electrical and Computer Engineering

 

Demonstration collection for miscellaneous ECE documents. Another alternative is to create an ECE sub-community under engineering, then create multiple ECE releated collections under that sub-community.

Recent Submissions

Discrimination experiments with the U.S. Army's standard metal detector 

Lloyd, Riggs; Chilaka, Sailaja; Leslie, Collins; Lowe, Larry; Weaver, Richard (2022-10-25)
[1] Discrimination experiments with the U. S. Army's standard hand-held metal detector (AN/PSS-12) are described. An appendix describes the functioning of the device as a metal detector, and the body of the paper discusses ...

The electrostatic characterization of an n-element planar array using the singularity expansion method 

Mooney, J; Riggs, L; Baginski, M; 0000-0002-7044-3152 (2022-09-28)
In this paper, the singularity expansion method (SEM) is used to describe the electrostatic charge distribution on an array of thin linear antennas placed in a uniform electric field. The SEM, which has primarily been used ...

Estimating the Center of Rotation of Tomographic Imaging Systems with Limited Projections 

Zhou, Huanyi; Reeves, Stanley J.; Panizzi, Peter R. (2021-04-02)
For a tomographic imaging system, image reconstruction quality is highly correlated with accurate determination of the true center of rotation (COR) location. A significant center offset error will introduce ringing, ...

AU Smart Cart Senior Design Project Report Fall 2012 

Poole, Brandon; Bennett, Geoffrey; Liner, James; Chumbler, Joshua; Johnson, John; Goyal, Harshit; Roppel, Thaddeus (2017-10-26)
Team 3 consists of six members working together to design and build a fully autonomous shopping cart. The purpose of the cart is to perform as a personal shopping assistant to the user as he/she shops in different environments. ...

Trust region methods for estimation of a complex exponential decay model in MRI with a single-shot or multi-shot trajectory (in review) 

Hu, Chenxi; Reeves, Stanley (2015-05-05)
Joint estimation of spin density, R2* decay and off-resonance frequency maps is very useful in many magnetic resonance imaging (MRI) applications. The standard multi-echo approach can achieve high accuracy but requires a ...

Characterization of Plenoptic Imaging Systems and Efficient Volumetric Estimation from Plenoptic Data 

Anglin, Paul; Reeves, Stanley J.; Thurow, Brian S. (2015-01-13)
Plenoptic imaging is a rapidly growing field driven by the ever-declining cost of imaging systems and the promise of image focus, perspective, and depth of field manipulation during post-processing. While plenoptic ...

On the Characterization and Reduction of Ill-Conditioning in Jointly Estimating Proton Density, T2* Decay and the Field Map 

Hu, Chenxi; Reeves, Stanley (2014-02-13)
We employ principal angles as a tool to demonstrate that the complex frequency is the main cause for ill-conditioning of model-based MRI reconstruction. We show that kernels of EPI and spiral trajectories have different ...

LaTeX seminar 

Reeves, Stanley (2010-06-28)